28 Types of High-risk Human Papilloma Virus (16/18 Typing) Nucleic Acid
Product name
HWTS-CC006A-28 Types of High-risk Human Papilloma Virus (16/18 Typing) Nucleic Acid Detection Kit (Fluorescence PCR)
Epidemiology
Cervical cancer is one of the most common malignant tumors of the female reproductive tract. Studies have shown that HPV persistent infections and multiple infections are one of the main causes of cervical cancer. Currently, the recognized effective treatments are still lack for cervical cancer caused by HPV, so early discovery and prevention of cervical infection caused by HPV is the key to preventing cervical cancer. It is of great significance to establish a simple, specific and rapid etiology diagnostic test for the clinical diagnosis and treatment of cervical cancer.
Channel
Reaction Mix | Channel | Type |
PCR-Mix1 | FAM | 18 |
VIC(HEX) | 16 | |
ROX | 31, 33, 35, 39, 45, 51, 52, 56, 58, 59, 66, 68 | |
CY5 | Internal Control | |
PCR-Mix2 | FAM | 6, 11, 54, 83 |
VIC(HEX) | 26, 44, 61, 81 | |
ROX | 40, 42, 43, 53, 73, 82 | |
CY5 | Internal Control |
Technical Parameters
Storage | Liquid: ≤-18℃ |
Shelf-life | 12 months |
Specimen Type | Cervical Swab、 Vaginal Swab 、Urine |
Ct | ≤28 |
CV | <5.0% |
LoD | 300Copies/mL |
Applicable Instruments | Applied Biosystems 7500 Real-Time PCR Systems Applied Biosystems 7500 Fast Real-Time PCR Systems QuantStudio®5 Real-Time PCR Systems SLAN-96P Real-Time PCR Systems LightCycler® 480 Real-Time PCR system LineGene 9600 Plus Real-Time PCR Detection System MA-6000 Real-Time Quantitative Thermal Cycler BioRad CFX96 Real-Time PCR System BioRad CFX Opus 96 Real-Time PCR System |
Work Flow
Recommended extraction reagent: Macro & Micro-Test Viral DNA/RNA Kit (HWTS-3017-50, HWTS-3017-32, HWTS-3017-48, HWTS-3017-96) (which can be used with Macro & Micro-Test Automatic Nucleic Acid Extractor (HWTS-3006C, HWTS-3006B)) by Jiangsu Macro & Micro-Test Med-Tech Co., Ltd. Add 200μL of normal saline to resuspend the pellet in step 2.1, and then the extraction should be conducted according to the instructions for use of this extraction reagent. The recommended elution volume is 80μL.
Recommended extraction reagent: QIAamp DNA Mini Kit (51304) or Macro & Micro-Test Viral DNA/RNA Column (HWTS-3020-50). Add 200μL of normal saline to resuspend the pellet in step 2.1, and then the extraction should be conducted according to the instructions for use of this extraction reagent. The extracted sample volume of samples are all 200μL, and the recommended elution volume is 100μL.