Best quality Malaria Pf Pv - Plasmodium Antigen Detection Kit(Colloidal Gold) – Macro & Micro-Test
Best quality Malaria Pf Pv - Plasmodium Antigen Detection Kit(Colloidal Gold) – Macro & Micro-Test Detail:
Product name
Plasmodium Antigen Detection Kit(Colloidal Gold)
Certificate
CE
Epidemiology
Malaria (Mal for short) is caused by Plasmodium, which is a single-celled eukaryotic organism, including Plasmodium falciparum, Plasmodium vivax, Plasmodium malariae Laveran, and Plasmodium ovale Stephens. It is a mosquito-borne and blood-borne parasitic disease that seriously endangers human health. Of the parasites that cause malaria in humans, Plasmodium falciparum is the deadliest and is most common in sub-Saharan Africa and causes most malaria deaths globally. Plasmodium vivax is the predominant malaria parasite in most countries outside sub-Saharan Africa.
Features
● Rapid: Read results within 15 minutes.
● Easy to use: Only 3 steps.
● Convenient: No instrument.
● Room temperature: Transportation & storage at 4-30℃ for 24 months.
● Accuracy: High sensitivity & specificity.
Technical Parameters
Target region | Plasmodium falciparum (P.f.), Plasmodium vivax (P.v.), Plasmodium ovale (P.o.) or Plasmodium malaria(P.m.) |
Storage temperature | 4℃-30℃ |
Transportation temperature | -20℃~45℃ |
Sample type | Human peripheral blood and venous blood |
Shelf life | 24 months |
Auxiliary instruments | Not required |
Extra Consumables | Not required |
Detection time | 15-20 mins |
Specificity | There is no cross-reactivity with influenza A H1N1 virus, H3N2 influenza virus, influenza B virus, dengue fever virus, Japanese encephalitis virus, respiratory syncytial virus, meningococcus, parainfluenza virus, rhinovirus, toxic bacillary dysentery, staphylococcus aureus, escherichia coli, streptococcus pneumoniae or klebsiella pneumoniae, salmonella typhi, rickettsia tsutsugamushi. The test results are all negative. |
Work Flow
1. Sampling
● Clean the fingertip with an alcohol pad.
● Squeeze the end of the fingertip and pierce it with the provided lancet.
2. Add the sample and solution
● Add 1 drop of sample to the “S” well of the cassette.
● Hold the buffer bottle vertically, and drop 3 drops (about 100 μL) into the “A” well.
3. Read the result (15-20mins)
*Pf: Plasmodium falciparum Pv:Plasmodium vivax Po: Plasmodium ovale Pm: Plasmodium malaria
Precautions:
1. Do not read the result after 20 mins.
2. After opening, please use the product within 1 hour.
3. Please add samples and buffers in strict accordance with the instructions.
Main Components
Catalogue Number | Packaging Size | Components | Specification | Quantity |
HWTS-OT057A | 1 test/kit | Test Cassette | 1pc/bag | 1bag |
Sample Extraction Solution | 0.2mL/bottle | 1bottle | ||
Lancet | 1pc/bag | 1bag | ||
Pipette | 1pc/bag | 1bag | ||
HWTS-OT057B | 20 test/kit |
Test Cassette | 1pc/bag | 20 bags |
Sample Extraction Solution | 4mL/bottle | 1 bottle | ||
Lancet | 20pcs/bag | 1bag | ||
Pipette | 20pcs/bag | 1bag |
Product detail pictures:
Related Product Guide:
Our enterprise aims to operating faithfully, serving to all of our prospects , and working in new technology and new machine frequently for Best quality Malaria Pf Pv - Plasmodium Antigen Detection Kit(Colloidal Gold) – Macro & Micro-Test , The product will supply to all over the world, such as: Seychelles, Frankfurt, Cairo, Our products are widely recognized and trusted by users and can meet continuously changing economic and social needs. We welcome new and old customers from all walks of life to contact us for future business relationships and mutual success!
By Ray from Norwegian - 2017.08.18 11:04
A good manufacturers, we have cooperated twice, good quality and good service attitude.
By Tyler Larson from British - 2017.01.11 17:15