Best-Selling Mycobacterium Tuberculosis Dna Detection Kit(Fluorescence Pcr) - Mycobacterium Tuberculosis DNA Detection Kit (Isothermal Amplification) – Macro & Micro-Test
Best-Selling Mycobacterium Tuberculosis Dna Detection Kit(Fluorescence Pcr) - Mycobacterium Tuberculosis DNA Detection Kit (Isothermal Amplification) – Macro & Micro-Test Detail:
Product name
Adenovirus Type 41 Nucleic Acid Detection Kit(Fluorescence PCR)
Certificate
CE
Packaging Size
1. Liquid product: 50 tests/kit
2. Freeze-dried product (penicillin vial): 20 tests/kit, 50 tests/kit
3. Freeze-dried product (8-tube strips): 48 tests/kit
Intended Use
This kit is used for the qualitative detection of adenovirus nucleic acid in stool samples in vitro.
Epidemiology
Adenovirus (Adv) belongs to the Adenovirus family. Adv can proliferate and cause disease in cells of the respiratory tract, gastrointestinal tract, urethra, and conjunctiva. It is mainly infected through the gastrointestinal tract, respiratory tract or close contact, especially in swimming pools with insufficient disinfection, which can increase the chance of transmission and cause outbreaks[1-2].
Adv mainly infects children. The gastrointestinal tract infections in children are mainly type 40 and 41 in group F. Most of them have no clinical symptoms, and some cause diarrhea in children. Its mechanism of action is to invade the small intestinal mucosa of children, making the intestinal mucosal epithelial cells smaller and shorter, and the cells degenerate and dissolve, resulting in intestinal absorption dysfunction and diarrhea. Abdominal pain and bloating may also occur, and in severe cases, the respiratory system, central nervous system, and extraintestinal organs such as liver, kidney, and pancreas may be involved and the disease may be aggravated[3-5].
Features
Multiplex PCR Amplification Technology
Internal control: Fully monitor the experimental process to ensure the quality of Experiments.
High sensitivity: 300Copies/mL
High specificity: No cross-reactivity with common respiratory pathogens or bacteria for more accurate results.
Rapid: Rapid PCR amplification, test results can be obtained in 40 minutes.
Channel
FAM: Adenovirus type 41 nucleic acid
VIC (HEX): Internal control
Amplification Conditions Setting
Step | Cycles | Temperature | Time | Collect Fluorescent Signals or Not |
1 | 1 cycle | 50℃ | 2mins | No |
2 | 1 cycle | 95℃ | 1min | No |
3 | 40 cycles | 95℃ | 5s | No |
55℃ | 15s | Yes |
Technical Parameters
Storage:
Liquid: ≤-18℃ In dark
Lyophilization: ≤30℃
Shelf-life: 12 months
Specimen Type: Stool samples
Ct: ≤38
CV: ≤5.0%
LoD: 300Copies/mL
Specificity: Use the kits to detect other respiratory pathogens (such as influenza A virus, influenza B virus, respiratory syncytial virus, parainfluenza virus, rhinovirus, human metapneumovirus, etc.) or bacteria (streptococcus pneumoniae, klebsiella pneumoniae, pseudomonas aeruginosa, acinetobacter baumannii, staphylococcus aureus, etc.) and common gastrointestinal pathogens group A rotavirus, escherichia coli, etc. There is no cross-reactivity with all the pathogens or bacteria mentioned above.
Applicable Instruments: It can match the mainstream fluorescent PCR instruments on the market.
ABI 7500 Real-Time PCR Systems
ABI 7500 Fast Real-Time PCR Systems
SLAN-96P Real-Time PCR Systems
QuantStudio®5 Real-Time PCR Systems
LightCycler®480 Real-Time PCR Systems
LineGene 9600 Plus Real-Time PCR Detection Systems
MA-6000 Real-Time Quantitative Thermal Cycler
Main Components
Liquid product
Catalogue Number |
Component (50 tests/kit) |
Specification |
Quantity |
Component Description |
HWTS-RT113B |
ADV 41 Reaction Buffer
|
1.25mL /vial |
1 vial |
Amplification reaction reagents, adenovirus type 41 primer probes, internal control primer probes, etc. |
ADV 41 Positive Control |
250μL/vial
|
1 vial |
Adenovirus and internal control plasmids mixture. |
|
ADV 41 Blank Control |
250μL/vial |
1 vial |
DNase/RNase free H2O |
Lyophilized product
Component | Character | Catalogue Number | Component Description | ||
HWTS-RT113A | HWTS-RT113C | HWTS-RT113Z | |||
Specification/Quantity(20 tests/kit) | Specification/Quantity(50 tests/kit) | Specification/Quantity(48 tests/kit) | |||
ADV 41 Reaction Buffer | lyophilized | 1 bottle | 1 bottle | 8-tube strips, 6 strips | Amplification reaction reagents, adenovirus type 41 primer probes, internal control primer probes, etc. |
ADV 41 Positive Control | lyophilized | 1 vial | 1 vial | 1 vial | Adenovirus and internal control plasmids mixture. |
ADV 41 Blank Control | Liquid | 1 vial, 250μL/vial | 1 vial, 250μL/vial | 1 vial, 250μL/vial | DNase/RNase free H2O |
ADV 41 Reconstituted Solution | Liquid | 1 vial, 650μL/vial | 1 vial, 1.25mL/vial | 1 vial, 1.21mL/vial | DNase/RNase free H2O, etc. |
Total PCR Solution
Option 1.
[References]
[1] Use of quantitative molecular diagnostic methods to identify causes of diarrhoea in children: a reanalysis of the GEMS case-control study[J]. Lancet, 2016, 388(10051):1291-1301.
[2] Burden and aetiology of diarrhoeal disease in infants and young children in developing countries (the Global Enteric Multicenter Study, GEMS): a prospective, case-control study.[J]. Lancet, 2013, 382(9888):209-222.
[3] Liu M, Worley S, Arrigain S, et al. Respiratory viral infections within one year after pediatric lung transplant[J]. Transplant Infectious Disease, 2010, 11(4):304-312.
[4] Dey R S, Ghosh S, Chawla-Sarkar M, et al. Circulation of a Novel Pattern of Infections by Enteric Adenovirus Serotype 41 among Children below 5 Years of Age in Kolkata, India[J]. Journal of Clinical Microbiology, 2011, 49(2):500-505.
[5] Lekana-Douki S E, Kombila-Koumavor C, Nkoghe D, et al. Molecular epidemiology of enteric viruses and genotyping of rotavirus A, adenovirus and astrovirus among children under 5 years old in Gabon[J]. International journal of infectious diseases: IJID: official publication of the International Society for Infectious Diseases, 2015, 34(C):90-95.
Product detail pictures:
Related Product Guide:
Based on domestic market and expand overseas business is our development strategy for Best-Selling Mycobacterium Tuberculosis Dna Detection Kit(Fluorescence Pcr) - Mycobacterium Tuberculosis DNA Detection Kit (Isothermal Amplification) – Macro & Micro-Test , The product will supply to all over the world, such as: Belgium, Malta, Buenos Aires, Since always, we adhering to the open and fair, share to get, the pursuit of excellence, and creation of valuevalues, adhere to theintegrity and efficient, trade-oriented, best way , best valve business philosophy. Together with our all over the world have branches and partners to develop new business areas, maximum common values. We sincerely welcome and together we share in global resources, opening up new career together with the chapter.
By Muriel from Egypt - 2018.11.28 16:25
Hope that the company could stick to the enterprise spirit of Quality, Efficiency, Innovation and Integrity, it will be better and better in the future.
By Athena from Lithuania - 2017.03.28 16:34