Discount Price Urinary Reproduction - Group B Streptococcus Nucleic Acid Detection Kit(Fluorescence PCR) – Macro & Micro-Test
Discount Price Urinary Reproduction - Group B Streptococcus Nucleic Acid Detection Kit(Fluorescence PCR) – Macro & Micro-Test Detail:
Product name
Group B Streptococcus Nucleic Acid Detection Kit(Fluorescence PCR)
Freeze-dried Group B Streptococcus Nucleic Acid Detection Kit(Fluorescence PCR)
Certificate
CE, FDA
Epidemiology
Group B Streptococcus (GBS), also known as streptococcus agalactiae, is a gram-positive opportunistic pathogen that normally inhabits the lower gastrointestinal and urogenital tracts of the human body. Approximately 10%-30 % of pregnant women have GBS vaginal sojourn.
Pregnant women are susceptible to GBS infection due to changes in the internal environment of the reproductive tract due to changes in hormone levels in the body, which will cause adverse pregnancy outcomes such as preterm labor, premature rupture of membranes, and stillbirth, and can also lead to puerperal infections in pregnant women.
Neonatal group B streptococcus is associated with perinatal infection and is an important pathogen of severe infectious diseases such as neonatal sepsis and meningitis. 40%-70% of mothers infected with GBS will transmit GBS to their newborns during delivery through the birth canal, causing serious neonatal infectious diseases such as neonatal sepsis and meningitis. If the newborns carry GBS, about 1%-3% will develop early invasive infection, of which 5% will result in death.
Features
● Multiplex PCR Amplification Technology.
● Internal control: Fully monitor the experimental process to ensure the quality of Experiments.
● High sensitivity: 1×103Copies/mL.
● High specificity: No cross-reactivity with common pathogens of reproductive tract infections.
● Convenient: One test for multiple results.
Channel
FAM: GBS target
VIC/HEX: Internal control
PCR Amplification Conditions Setting
Step | Cycles | Temperature | Time | Collect Fluorescent Signals or Not |
1 | 1 cycle | 50℃ | 2mins | No |
2 | 1 cycle | 95℃ | 5mins | No |
3 | 40 cycles | 95℃ | 10s | No |
58℃ | 30s | Yes |
Technical Parameters
Storage | Liquid:≤-18℃ in dark; Lyophilization: ≤30℃ in dark |
Shelf-life | 12 months |
Specimen Type | Genital and Rectal Secretions |
Ct | ≤38 |
CV | ≤5.0% |
LoD | 1×103Copies/mL |
Covering Subtypes | Detect group B streptococcus serotypes (I a, I b, I c, II, III, IV, V, VI, VII, VIII, IX and ND) and the results are all positive. |
Specificity: Detect other genital tract and rectal swab samples such as candida albicans, trichomonas vaginalis, chlamydia trachomatis, ureaplasma urealyticum, neisseria gonorrhoeae, mycoplasma hominis, mycoplasma genitalium, herpes simplex virus, human papilloma virus , lactobacillus, gardnerella vaginalis, staphylococcus aureus, national negative reference N1-N10 (streptococcus pneumoniae, streptococcus pyogenes, streptococcus thermophilus, streptococcus mutans, streptococcus pyogenes, lactobacillus acidophilus bacillus, lactobacillus reuteri, escherichia coli DH5α, candida albicans) and human genomic DNA, the results are all negative for group B streptococcus.
Applicable Instruments: It can match the mainstream fluorescent PCR instruments on the market.
SLAN-96P Real-Time PCR Systems.
ABI 7500 Real-Time PCR Systems.
QuantStudio®5 Real-Time PCR Systems.
LightCycler®480 Real-Time PCR Systems.
LineGene 9600 Plus Real-Time PCR Detection Systems.
MA-6000 Real-Time Quantitative Thermal Cycler.
Main Components
Group B Streptococcus Nucleic Acid Detection Kit(Fluorescence PCR)
Catalogue Number | Component (50 tests/kit) | Specification | Quantity | Component Description |
HWTS-UR027A | GBS Reaction Buffer | 1.25mL /vial | 1 vial | GBS gene and internal control specific primers, fluorescent probes, UNG enzyme and Taq enzyme in a certain proportion |
GBS Positive Control | 600μL/vial | 1 vial | Mixture of GBS gene recombinant plasmid and internal control recombinant plasmid | |
GBS Blank Control | 600μL/vial | 1 vial | DNase/RNase free H2O |
Freeze-dried Group B Streptococcus Nucleic Acid Detection Kit(Fluorescence PCR)
Component |
Character |
Catalogue Number |
Component Description |
|
HWTS-UR028A | HWTS-UR028B | |||
Specification/ Quantity (20 tests/kit) |
Specification/ Quantity (50 tests/kit) |
|||
GBS Reaction Buffer | lyophilization | 1 bottle | 1 bottle | Contains GBS gene and internal control specific primers, fluorescent probes, UNG enzyme and Taq enzyme and prepared in a certain proportion |
GBS Positive Control | lyophilization | 1 vial | 1 vial | GBS gene recombinant plasmids and internal control recombinant plasmids mix |
GBS Blank Control | Liquid | 1 vial, 600μL/vial | 1 vial, 600μL/vial | DNase/RNase free H2O |
Reconstituted Solution | Liquid | 1 vial, 1mL/vial | 1 vial, 1.45mL/vial | DNase/RNase free H2O, etc. |
Total PCR Solution
Option 1.
Option 2.
Reference
[1] Schrag S, Gorwitz R, Fultzbutts K, et al. Prevention of perinatal group B streptococcal disease. Revised guidelines from CDC.[J]. Pediatric Infectious Disease Journal, 2010, 59(RR-10):1-31.
[2] Yuan XY, Liu HZ, Liu JF, Sun Y, Song Y. Pathogenic mechanism, detection methods and clinical significance of group B Streptococcus. Future Microbiol. 2021 Jun; 16:671-685.
[3] Furfaro LL, Chang BJ, Payne MS. Perinatal Streptococcus agalactiae Epidemiology and Surveillance Targets. Clin Microbiol Rev. 2018 Aug 15; 31(4):e00049-18.
[4] Shi CY, Qu SH, Yang L, Yang HX. [Detection of maternal colonization of group B streptococcus in late pregnancy by real-time polymerase chain reaction and its effect on perinatal outcome]. Zhonghua Fu Chan Ke Za Zhi. 2010 Jan; 45(1):12-6. Chinese.
[5] Ferrieri P, Flores AE. Surface protein expression in group B streptococcal invasive isolates. Adv Exp Med Biol. 1997;418:635-7.
Product detail pictures:
Related Product Guide:
Good quality comes 1st; assistance is foremost; business enterprise is cooperation is our business enterprise philosophy which is regularly observed and pursued by our company for Discount Price Urinary Reproduction - Group B Streptococcus Nucleic Acid Detection Kit(Fluorescence PCR) – Macro & Micro-Test , The product will supply to all over the world, such as: Philippines, belarus, Canada, With the enterprising spirit of high efficiency, convenience, practicality and innovation, and in line with such serving guidance of good quality but better price, and global credit, we are striving to cooperate with the automobile parts companies all over the world to make a win-win partnership.