Enterovirus 71 (EV71)
Product name
HWTS-EV003- Enterovirus 71 (EV71) Nucleic Acid Detection Kit (Fluorescence PCR)
Epidemiology
Hand-foot-mouth disease is an infectious disease caused by enteroviruses (EV). Currently, 108 kinds of serotypes of enteroviruses have been found, which are divided into four groups: A, B, C and D. Among them, enterovirus EV71 and CoxA16 are the main pathogens. The disease mostly occurs in children under 5 years old, and can cause herpes on the hands, feet, mouth and other parts. A small number of children will develop complications such as myocarditis, pulmonary edema, and aseptic meningoencephalitis.
Channel
FAM | EV71 |
ROX |
Internal Control |
Technical Parameters
Storage |
≤-18℃ |
Shelf-life | 9 months |
Specimen Type | Oropharyngeal swab,Herpes fluid |
Ct | ≤35 |
CV | <5.0% |
LoD | 500Copies/mL |
Applicable Instruments | Applied Biosystems 7500 Real-Time PCR Systems
Applied Biosystems 7500 Fast Real-Time PCR Systems QuantStudio®5 Real-Time PCR Systems SLAN-96P Real-Time PCR Systems LightCycler®480 Real-Time PCR Systems LineGene 9600 Plus Real-Time PCR Detection Systems MA-6000 Real-Time Quantitative Thermal Cycler BioRad CFX96 Real-Time PCR System BioRad CFX Opus 96 Real-Time PCR System |
Work Flow
Option 1.
Recommended extraction reagent: Macro & Micro-Test Sample Release Reagent (HWTS-3005-8), and the extraction should be conducted according to the instruction for use. The extracted samples are the oropharyngeal swabs or herpes fluid samples from patients that collected on site. Add the collected swabs into the Macro & Micro-Test Sample Release Reagent (HWTS-3005-8) directly, vortex and mix well, place at room temperature for 5 minutes, take them out and then invert to mix well, to obtain the RNA of each sample.
Option 2.
Recommended extraction reagent: Macro & Micro-Test General DNA/RNA Kit (HWTS-3017-50, HWTS-3017-32, HWTS-3017-48, HWTS-3017-96) (which can be used with Macro & Micro-Test Automatic Nucleic Acid Extractor (HWTS-3006C, HWTS-3006B)) by Jiangsu Macro & Micro-Test Med-Tech Co., Ltd., and the extraction should be conducted according to the instruction for use. The extracted sample volume is 200µL, and the recommended elution volume is 80µL.
Option3.
Recommended extraction reagent: QIAamp Viral RNA Mini Kit (52904) by QIAGEN or TIANamp Virus DNA/RNA Kit (YDP315-R), and the extraction should be conducted in strict accordance with the instruction for use. The extracted sample volume is 140μL, and the recommended elution volume is 60µL.