Factory wholesale Instruments & Consumables - Macro & Micro-Test Sample Release Reagent – Macro & Micro-Test

Short Description:


Product Detail

Product Tags

Related Video

Feedback (2)

Our staff through skilled training. Skilled skilled knowledge, potent sense of company, to satisfy the provider requirements of consumers for Hcv Genotype Assay, Gbs Test, Vitamin D Detection Kit, We are looking forward to establishing cooperative relationships with you. Please contact us for more information.
Factory wholesale Instruments & Consumables - Macro & Micro-Test Sample Release Reagent – Macro & Micro-Test Detail:

Product name

Macro & Micro-Test Sample Release Reagent

Certificate

CE, FDA, NMPA

Features

Rapid: only 5 mins.

Easy: only 3 steps (1.add the sample 2.Mix upside and down 10 times 3. Leave it for 5 mins).

Main components

Name Main components Component specifications Quantity
Sample Release reagent Dithiothreitol, sodium dodecyl sulfate (SDS), RNase inhibitor, surfactant, purified water 0.5mL/Vial 50 Vial

Note: Components in different batches of kits are not interchangeable.

Storage conditions and shelf life

Store and transport at room temperature. The shelf life is 24 months. 

Applicable instruments

Instruments and equipment during sample processing, such as pipettes, vortex mixers, water baths, etc. 

Sample requirements

Freshly collected oropharyngeal swabs, nasopharyngeal swabs.

Precision

When this kit is used for extraction from the in-house precision reference CV for 10 replicates, the coefficient of variation (CV, %) of Ct value is not more than 10%.

Inter-batch difference

When the in-house precision reference is tested on three batches of kits under trial production upon repeated extraction and, the coefficient of variation (CV, %) of Ct value is not more than 10%.

Performance comparison

● Extraction efficiency comparsion

Efficiency comparsion of magnetic beads method and sample releaser

concentration
copies/mL

magnetic beads method

sample releaser

orfab

N

orfab

N

20000

28.01

28.76

28.6

29.15

2000

31.53

31.9

32.35

32.37

500

33.8

34

35.25

35.9

200

35.25

35.9

35.83

35.96

100

36.99

37.7

38.13

undet

The extraction efficiency of sample releaser was similar to that of magnetic beads method, and the concentration of pathogen could be 200Copies/mL.

● CV value comparison

Repeatability of sample releaser extraction

concentration:5000Copies/mL

ORF1ab

N

30.17

30.38

30.09

30.36

30.36

30.26

30.03

30.48

30.14

30.45

30.31

30.16

30.38

30.7

30.72

30.79

CV

0.73%

0.69%

When tested at 5,000 copies /mL, the CV of orFab and N was 0.73% and 0.69%, respectively.

Macro & Micro-Test Sample Release Reagent10


Product detail pictures:

Factory wholesale Instruments & Consumables - Macro & Micro-Test Sample Release Reagent – Macro & Micro-Test detail pictures

Factory wholesale Instruments & Consumables - Macro & Micro-Test Sample Release Reagent – Macro & Micro-Test detail pictures

Factory wholesale Instruments & Consumables - Macro & Micro-Test Sample Release Reagent – Macro & Micro-Test detail pictures

Factory wholesale Instruments & Consumables - Macro & Micro-Test Sample Release Reagent – Macro & Micro-Test detail pictures

Factory wholesale Instruments & Consumables - Macro & Micro-Test Sample Release Reagent – Macro & Micro-Test detail pictures


Related Product Guide:

The shopper satisfaction is our primary focus on. We uphold a consistent level of professionalism, quality, credibility and repair for Factory wholesale Instruments & Consumables - Macro & Micro-Test Sample Release Reagent – Macro & Micro-Test , The product will supply to all over the world, such as: Anguilla, moldova, Colombia, We follow superior mechanism to process these products that ensure optimum durability and reliability of the products. We follow latest effective washing and straightening processes that allow us to offer unmatched quality of products for our clients. We continually strive for perfection and all our efforts are directed towards attaining complete client satisfaction.
  • The company keeps to the operation concept scientific management, high quality and efficiency primacy, customer supreme, we have always maintained business cooperation. Work with you,we feel easy!
    5 Stars By Victor from Madagascar - 2018.08.12 12:27
    Cooperate with you every time is very successful, very happy. Hope that we can have more cooperation!
    5 Stars By Hannah from Sudan - 2018.05.15 10:52
    Write your message here and send it to us