Our growth depends on the superior equipment ,exceptional talents and continuously strengthened technology forces for Hcv Genotype Assay, Eml4-Alk Fusion Testing, Monkeypox Kit, We have now deep cooperation with hundreds of factories all over China. The goods we give can match with your different calls for. Choose us, and we won't make you regret!
Good User Reputation for Respiratory Pathogen Testing Kit - RT-PCR kit for detecting six kinds of respiratory pathogens – Macro & Micro-Test Detail:

Product name

Real time fluorescent RT-PCR kit for detecting six kinds of respiratory pathogens

Certificate

CE

Epidemiology

Corona Virus Disease 2019, referred to as “COVID-19″, refers to the pneumonia caused by SARS-CoV-2 infection. SARS-CoV-2 is a coronavirus belonging to the β genus. COVID-19 is an acute respiratory infectious disease, and the population is generally susceptible. At present, the source of infection is mainly patients infected by SARS-CoV-2, and asymptomatic infected persons may also become the source of infection. Based on the current epidemiological investigation, the incubation period is 1-14 days, mostly 3-7 days. Fever, dry cough and fatigue are the main manifestations. A few patients had nasal congestion, runny nose, sore throat, myalgia and diarrhea.

Influenza, commonly known as “flu”, is an acute respiratory infectious disease caused by influenza virus. It is highly infectious. It is mainly transmitted by coughing and sneezing. It usually breaks out in spring and winter. Influenza viruses are divided into influenza A, IFV A, influenza B, IFV B, and Influenza C, IFV C three types, all belong to sticky virus, cause human disease mainly for influenza A and B viruses, it is a single-stranded, segmented RNA virus. Influenza A virus is an acute respiratory infection, including H1N1, H3N2 and other subtypes, which are prone to mutation and outbreak worldwide. “Shift” refers to the mutation of influenza A virus, resulting in the emergence of a new virus “subtype”. Influenza B viruses are divided into two lineages, Yamagata and Victoria. Influenza B virus only has antigenic drift, and it evades the human immune system’s surveillance and elimination through its mutation. However, the evolution speed of influenza B virus is slower than that of human influenza A virus. Influenza B virus can also cause human respiratory infections and lead to epidemics.

Adenovirus (AdV) belongs to mammalian adenovirus, which is a double stranded DNA virus without envelope. At least 90 genotypes have been found, which can be divided into A-G 7 subgenera. AdV infection can cause a variety of diseases, including pneumonia, bronchitis, cystitis, eye conjunctivitis, gastrointestinal diseases and encephalitis. Adenovirus pneumonia is one of the more severe types of community-acquired pneumonia in children, accounting for about 4%-10% of community-acquired pneumonia.

Mycoplasma pneumoniae (MP) is a kind of the smallest prokaryotic microorganism, which is between bacteria and virus, with cell structure but no cell wall. MP mainly causes human respiratory tract infection, especially in children and young people. It can cause human mycoplasma pneumonia, children’s respiratory tract infection and atypical pneumonia. The clinical manifestations are various, most of which are severe cough, fever, chills, headache, sore throat. Upper respiratory tract infection and bronchial pneumonia are the most common. Some patients can develop from upper respiratory tract infection to severe pneumonia, severe respiratory distress and death may occur.

Respiratory syncytial virus (RSV) is an RNA virus, belonging to the paramyxoviridae family. It is transmitted by air droplets and close contact and is the main pathogen of lower respiratory tract infection in infants. Infants infected with RSV may develop severe bronchiolitis (referred to as bronchiolitis) and pneumonia, which are related to asthma in children. Infants have severe symptoms, including high fever, rhinitis, pharyngitis and laryngitis, and then bronchiolitis and pneumonia. A few sick children can be complicated with otitis media, pleurisy and myocarditis, etc. Upper respiratory tract infection is the main symptom of infection in adults and older children.

Features

● Multiplex PCR Amplification Technology.
● Internal control: Fully monitor the experimental process to ensure the quality of Experiments.
● High sensitivity: 300Copies/mL.
● Convenient: One test for multiple results.
● Comprehensive: Wide coverage of pathogen types, with detection of various subtypes available.

Channel

The name of the channel R6 Reaction Buffer A R6 Reaction Buffer B
FAM SARS-CoV-2 HAdV
VIC/HEX Internal Control Internal Control
CY5 IFV A MP
ROX IFV B RSV

PCR Amplification Conditions Setting

Step Cycles Temperature Time Collect Fluorescent Signals or Not
1 1 cycle 50℃ 2mins No
2 1 cycle 95℃ 5mins No
3 45 cycles 95℃ 15s No
55℃ 30s Yes

Technical Parameters

Storage  ≤-18℃ In dark
Shelf-life  9 months
Specimen Type  Whole blood, Plasma, Serum
Ct  ≤40
CV  ≤5.0%
LoD  300Copies/mL

Specificity: Cross-reactivity results showed that there was no cross reaction between the kit and human coronavirus SARSr-CoV, MERSr-CoV, HCoV-OC43, HCoV-229E, HCoV-HKU1, HCoV-NL63, parainfluenza virus type 1, 2, 3, rhinovirus A, B, C, chlamydia pneumoniae, human metapneumovirus, enterovirus A, B, C, D, human pulmonary virus, epstein-barr virus, measles virus, human cytomegalo virus, rotavirus, norovirus, parotitis virus, varicella-zoster virus, legionella, bordetella pertussis, haemophilus influenzae, staphylococcus aureus, streptococcus pneumoniae, s. pyogenes, klebsiella pneumoniae, mycobacterium tuberculosis, smoke aspergillus, candida albicans, candida glabrata, pneumocystis jiroveci and newborn cryptococcus and human genomic nucleic acid.

Applicable Instruments: It can match the mainstream fluorescent PCR instruments on the market.
SLAN-96P Real-Time PCR Systems.
ABI 7500 Real-Time PCR Systems.
ABI 7500 Fast Real-Time PCR Systems.
QuantStudio®5 Real-Time PCR Systems.
LightCycler®480 Real-Time PCR Systems.
LineGene 9600 Plus Real-Time PCR Detection Systems.
MA-6000 Real-Time Quantitative Thermal Cycler.
BioRad CFX96 Real-Time PCR System, BioRad.
CFX Opus 96 Real-Time PCR System.

Main Components

Catalogue Number Component (50 tests/kit) Specification Quantity Component Description
HWTS-OT058A R6 ReactionBuffer 1.6mL/vial 1 vial Amplification reaction buffer, dNTP
R6 Primers andProbes Mix A 195μL/vial 1 vial Specific primers and probes of pathogens including SARS-CoV-2, IFV A, IFV B and internal control
R6 Primers andProbes Mix B 195μL/vial 1 vial Specific primers and probes of pathogens including AdV, MP, RSV and internal control
R6 Enzyme Mix 160μL/vial 1 vial Taq enzyme, reverse transcriptase, UDG enzyme
R6 PositiveControl 750μL/vial 1 vial Virus target gene plasmids and internal control plasmids mix
R6 Blank Control 750μL/vial 1 vial DNase/RNase free H2O

Total PCR Solution

Total PCR Solution

References

[1] Rai P, Kumar B K, Deekshit V K, et al. Detection technologies and recent developments in the diagnosis of COVID-19 infection[J]. Applied Microbiology and Biotechnology, 2021, 105(5).
[2] Marando M, Tamburello A, Gianella P. False-Negative Nasopharyngeal Swab RT-PCR Assays in Typical COVID-19: Role of Ultra-low-dose Chest CT and Bronchoscopy in Diagnosis[J]. European Journal of Case Reports in Internal Medicine, 2020, 7(7).
[3] Peiris J, Poon L, Guan Y. Emergence of a novel swine-origin influenza A virus (S-OIV) H1N1 virus in humans[J]. Journal of clinical virology: the official publication of the Pan American Society for Clinical Virology, 2009, 45(3):169-173.
[4] Yamashita M, Krystal M, Fitch W M, et al. Influenza B virus evolution: Co-circulating lineages and comparison of evolutionary pattern with those of influenza A and C viruses[J]. Virology, 1988, 163(1):112-122.
[5] Sloots T P, Whiley D M , Syrmis M W , et al. lightcycler reverse transcriptase pcr virus in respiratory samples by detection of human respiratory syncytial[J]. 2019.
[6] Yw A, Ek B, Ar B, et al. Comparison of the Idylla Respiratory (IFV-RSV) panel with the GeneXpert Xpert Flu/RSV assay: a retrospective study with nasopharyngeal and midturbinate samples[J]. Diagnostic Microbiology and Infectious Disease, 2019, 94( 1):33-37.
[7] Leong N K C, Chu D K W, Chu J T S, et al. A six﹑lex droplet digital RT ㏄ CR assay for seasonal influenza virus typing, subtyping, and lineage determination[J]. Influenza and Other Respiratory Viruses, 2020.
[8] Pol F, S Quéguiner, Gorin S, et al. Validation of commercial real-time RT-PCR kits for detection of influenza A viruses in porcine samples and differentiation of pandemic (H1N1) 2009 virus in pigs[J]. Journal of Virological Methods, 2011, 171(1):241-247.
[9] Coiras M T, Aguilar J C, M.L. García, et al. Simultaneous detection of fourteen respiratory viruses in clinical specimens by two multiplex reverse transcription nested-PCR assays.[J]. Journal of Medical Virology, 2004, 72(3):484.
[10] Fre’ de’ric Raymond, Julie Carbonneau, Nancy Boucher et al. Comparison of Automated Microarray Detection with Real-Time PCR Assays for Detection of Respiratory Viruses in Specimens Obtained from Children [J]. Journal of Clinical Microbiology,2009, 47(3):740-750.
[11] Metzgar D, Gibbins C, Hudson N R, et al. Evaluation of multiplex type-specific real-time PCR assays using the LightCycler and joint biological agent identification and diagnostic system platforms for detection and quantitation of adult human respiratory adenoviruses.[J]. Journal of Clinical Microbiology, 2010, 48(4):1397-1403.
[12] Tatsumi C, Iizuka S, Mita T, et al. The first identification of human adenovirus 57 (HAdV-57) in Japan[J]. Japanese journal of infectious diseases, 2018, 71(4).
[13] Kanwar N , Hassan F , Nguyen A , et al. Head-to-head comparison of the diagnostic accuracies of BD Veritor System RSV and Quidel Sofia RSV FIA systems for respiratory syncytial virus (RSV) diagnosis.[J]. Journal of Clinical Virology, 2015, 65:83-86.
[14] Bing S , He H , Zheng W , et al. Emergent severe acute respiratory distress syndrome caused by adenovirus type 55 in immunocompetent adults in 2013: a prospective observational study[J]. Critical Care, 2014, 18(4):456.
[15] CaoB, HuangGH, PuZH, et al.Emergence of community-acquired adenovirus type 55 as a cause of community-onset pneumonia[J].Chest, 2014, 145(1):79-86.


Product detail pictures:

Good User Reputation for Respiratory Pathogen Testing Kit - RT-PCR kit for detecting six kinds of respiratory pathogens – Macro & Micro-Test detail pictures

Good User Reputation for Respiratory Pathogen Testing Kit - RT-PCR kit for detecting six kinds of respiratory pathogens – Macro & Micro-Test detail pictures

Good User Reputation for Respiratory Pathogen Testing Kit - RT-PCR kit for detecting six kinds of respiratory pathogens – Macro & Micro-Test detail pictures

Good User Reputation for Respiratory Pathogen Testing Kit - RT-PCR kit for detecting six kinds of respiratory pathogens – Macro & Micro-Test detail pictures


Related Product Guide:

Based on domestic market and expand overseas business is our development strategy for Good User Reputation for Respiratory Pathogen Testing Kit - RT-PCR kit for detecting six kinds of respiratory pathogens – Macro & Micro-Test , The product will supply to all over the world, such as: Naples, Netherlands, Sri Lanka, Since its foundation , the company keeps living up to the belief of honest selling , best quality , people-orientation and benefits to customers. We are doing everything to offer our customers with best services and best products . We promise that we'll be responsible all the way to the end once our services begin.
  • The company account manager has a wealth of industry knowledge and experience, he could provide appropriate program according our needs and speak English fluently.
    5 Stars By Sophia from Cyprus - 2017.08.15 12:36
    Adhering to the business principle of mutual benefits, we have a happy and successful transaction, we think we will be the best business partner.
    5 Stars By Agnes from Birmingham - 2018.06.21 17:11
    Write your message here and send it to us