Hepatitis A Virus

Short Description:

This kit is suitable for the qualitative detection of hepatitis A virus (HAV) nucleic acid in serum samples and stool samples in vitro.


Product Detail

Product Tags

Product name

HWTS-HP005 Hepatitis A Virus Nucleic Acid Detection Kit  (Fluorescence PCR)

Epidemiology

Hepatitis A virus (HAV) is the main cause of acute viral hepatitis. The virus is a positive-sense single-stranded RNA virus and belongs to the Hepadnavirus genus of the family Picornaviridae. Hepatitis A virus, mainly transmitted by the fecal-oral route, resistant to heat, acids, and most organic solvents, can survive for a long time in shellfish, water, soil, or seabed sediments[1-3]. It is transmitted by having contaminated food or water, or directly it transmitted from person-to-person. Foods associated with HAV include oysters and clams, strawberries, raspberries, blueberries, dates, green leafy vegetables, and semi-dried tomatoes[4‒6].

Channel

FAM HAV nucleic acid
ROX

Internal Control

Technical Parameters

Storage

≤-18℃

Shelf-life Liquid: 9 months, Lyophilized: 12 months
Specimen Type Serum/stool
Tt ≤38
CV ≤5.0%
LoD 2 Copies/μL
Specificity Use the kits to test other hepatitis viruses such as hepatitis B, C, D, E, enterovirus 71, coxsackie virus, Epstein-Barr virus, norovirus, HIV and human genome.There is no cross-reactivity.
Applicable Instruments Applied Biosystems 7500 Real-Time PCR System

Applied Biosystems 7500 Fast Real-Time PCR Systems

QuantStudio®5 Real-Time PCR Systems

SLAN-96P Real-Time PCR Systems(Hongshi Medical Technology Co., Ltd.)

LightCycler®480 Real-Time PCR system

LineGene 9600 Plus Real-Time PCR Detection System (FQD-96A, Hangzhou Bioer technology), MA-6000 Real-Time Quantitative Thermal Cycler

BioRad CFX96 Real-Time PCR System

BioRad CFX Opus 96 Real-Time PCR System

Work Flow

Serum samples

Option 1.

Macro & Micro-Test General DNA/RNA Kit (HWTS-3017-50, HWTS-3017-32, HWTS-3017-48, HWTS-3017-96) and Macro & Micro-Test Automatic Nucleic Acid Extractor (HWTS-3006C, HWTS-3006B). It should be extracted according to the instructions. The recommended elution volume is 80µL.

Option 2.

TIANamp Virus DNA/RNA Kit (YDP315-R) manufactured by Tiangen Biotech (Beijing) Co., Ltd. It should be extracted according to the instructions. The extracted sample volume is 140μL. The recommended elution volume is 60µL.

2.Stool Samples

Macro & Micro-Test General DNA/RNA Kit (HWTS-3017-50, HWTS-3017-32, HWTS-3017-48, HWTS-3017-96) and Macro & Micro-Test Automatic Nucleic Acid Extractor (HWTS-3006C, HWTS-3006B). It should be extracted according to the instructions. The recommended elution volume is 80µL.


  • Previous:
  • Next:

  • Write your message here and send it to us