High Quality for Hpv Genotyping Pcr - 14 High-Risk HPV with 16/18 Genotyping Test Kit (Fluorescence PCR) – Macro & Micro-Test
High Quality for Hpv Genotyping Pcr - 14 High-Risk HPV with 16/18 Genotyping Test Kit (Fluorescence PCR) – Macro & Micro-Test Detail:
Product name
14 High-Risk HPV with 16/18 Genotyping Test Kit (Fluorescence PCR)
Freeze-dried 14 Types of High-risk Human Papilloma Virus (16/18 Typing) Nucleic Acid Detection Kit (Fluorescence PCR)
Certificate
CE
Epidemiology
Cervical cancer is one of the most common malignant tumors in the female reproductive tract. It has been shown that persistent HPV infection and multiple infections are one of major causes of cervical cancer. Currently there is still a lack of generally accepted effective treatments for cervical cancer caused by HPV. Therefore, early detection and prevention of cervical infection caused by HPV are the keys to prevention of cervical cancerization. Establishment of simple, specific and rapid diagnostic tests for pathogens is of great significance for clinical diagnosis of cervical cancer.
Features
● Multiplex PCR Amplification Technology
● Internal control: Fully monitor the experimental process to ensure the quality of Experiments.
● High sensitivity: 25 Copies/reaction
● High specificity: No cross-reactivity with common respiratory pathogens for more accurate results.
● Convenient: One test for multiple results
Channel
Channel | Type |
FAM | HPV 18 |
VIC/HEX | HPV 16 |
ROX | HPV 31, 33, 35, 39, 45,51,52, 56, 58, 59, 66, 68 |
CY5 | Internal Control |
PCR Amplification Conditions Setting
Step | Cycles | Temperature | Time | Collect Fluorescent Signals or Not |
1 | 1 cycle | 50℃ | 2mins | No |
2 | 1 cycle | 95℃ | 10mins | No |
3 | 10 cycles | 95℃ | 15 s | No |
62℃ | 20 s | No | ||
4 | 30 cycles | 95℃ | 15 s | No |
58℃ | 30 s | Yes |
Technical Parameters
Storage | ≤-18℃ in dark |
Shelf-life | 12 months |
Specimen Type | Cervical exfoliated cells |
Ct | ≤28 |
CV | ≤5.0% |
LoD | Liquid |
Specificity | No cross-reactivity with common reproductive tract pathogens (such as ureaplasma urealyticum, genital tract chlamydia trachomatis, candida albicans, neisseria gonorrhoeae, trichomonas vaginalis, mold, gardnerella and other HPV types not covered in the kit, etc). |
Applicable Instruments | It can match the mainstream fluorescent PCR instruments on the market. |
SLAN-96P Real-Time PCR Systems | |
ABI 7500 Real-Time PCR Systems | |
QuantStudio®5 Real-Time PCR Systems | |
LightCycler®480 Real-Time PCR Systems | |
LineGene 9600 Plus Real-Time PCR Detection Systems | |
MA-6000 Real-Time Quantitative Thermal Cycle |
Main Components
14 High-Risk HPV with 16/18 Genotyping Test Kit (Fluorescence PCR)
Catalogue Number | Component (50 tests/kit) | Specification | Quantity | Component Description |
HWTS-CC007A | HPV Reaction Buffer | 950μL/vial | 1 vial | Amplification reagents |
HPV Primer and Probe Mix | 300μL/vial | 1 vial | Mix of various types of primers and probes | |
HPV Positive Control | 600μL/vial | 1 vial | Mix of HPV 16, 18, 33 and internal control Templates | |
HPV Blank Control | 600μL/vial | 1 vial | DNase/RNase free H2O |
Freeze-dried 14 Types of High-risk Human Papilloma Virus (16/18 Typing) Nucleic Acid Detection Kit (Fluorescence PCR)
Component | Character | Catalogue Number | Component Description | |
HWTS-CC010A | HWTS-CC010B | |||
Specification/Quantity (20 tests/kit) |
Specification/Quantity (50 tests/kit) |
|||
HPV Reaction Buffer | Lyophilization | 1 bottle | 1 bottle | Amplification reaction reagents and kinds of primers, probes |
HPV Positive Control | Lyophilization | 1 vial | 1 vial | Mixture of HPV16, 18, 33 and their internal control plasmids |
HPV Blank Control | Liquid | 1 vial, 600μL/vial | 1 vial, 600μL/vial | DNase/RNase free H2O |
Reconstituted Solution | Liquid | 1 vial, 1mL/vial | 1 vial, 1.45mL/vial | DNase/RNase free H2O, etc. |
Total PCR Solution
Option 1.
Option 2.
References
1. Guo Yumei, Sun Jie, Chen Yadan, et al. HPV testing and its significance in the diagnosis of cervical cancer [J]. Chinese Journal of Laboratory Diagnosis, 2009,13: 1306-1308.
2. Li Hua, Gao Guolan. Advance in research on HPV and cervical cancer [J]. The Practical Journal of Cancer, 2007, 22: 420-422.
3. He Guishan. Advance in research on HPV detection methods [J]. Gansu Medical Journal, 2009, 28: 182-183.
4. Ning Tang, Shihai Huang, Brian Erickson, et al. High-risk HPV detection and concurrent HPV 16 and 18 typing with abbott realtime high risk HPV test [J]. Journal of Clinical Virology, 2009, 45: S25-S28.
Product detail pictures:
Related Product Guide:
Our business puts emphasis over the administration, the introduction of talented staff, plus the construction of employees building, striving hard to boost the standard and liability consciousness of staff members. Our corporation successfully attained IS9001 Certification and European CE Certification of High Quality for Hpv Genotyping Pcr - 14 High-Risk HPV with 16/18 Genotyping Test Kit (Fluorescence PCR) – Macro & Micro-Test , The product will supply to all over the world, such as: Algeria, Karachi, UK, Our team knows well the market demands in different countries, and is capable of supplying suitable quality products and solutions at the best prices to different markets. Our company has already set up a experienced, creative and responsible team to develop clients with the multi-win principle.
By Frances from Armenia - 2017.03.08 14:45
Products and services are very good, our leader is very satisfied with this procurement, it is better than we expected,
By Henry from South Africa - 2018.06.12 16:22