High Quality for Isothermal Amplification - Macro & Micro-Test Sample Release Reagent – Macro & Micro-Test

Short Description:


Product Detail

Product Tags

Related Video

Feedback (2)

Every single member from our higher effectiveness product sales staff values customers' requires and organization communication for Kras, Hbv Dna Pcr Test, H Pylori Antigen, We focus on to make excellent quality products to supply service for our clients to establish long-term win-win relationship.
High Quality for Isothermal Amplification - Macro & Micro-Test Sample Release Reagent – Macro & Micro-Test Detail:

Product name

Macro & Micro-Test Sample Release Reagent

Certificate

CE, FDA, NMPA

Features

Rapid: only 5 mins.

Easy: only 3 steps (1.add the sample 2.Mix upside and down 10 times 3. Leave it for 5 mins).

Main components

Name Main components Component specifications Quantity
Sample Release reagent Dithiothreitol, sodium dodecyl sulfate (SDS), RNase inhibitor, surfactant, purified water 0.5mL/Vial 50 Vial

Note: Components in different batches of kits are not interchangeable.

Storage conditions and shelf life

Store and transport at room temperature. The shelf life is 24 months. 

Applicable instruments

Instruments and equipment during sample processing, such as pipettes, vortex mixers, water baths, etc. 

Sample requirements

Freshly collected oropharyngeal swabs, nasopharyngeal swabs.

Precision

When this kit is used for extraction from the in-house precision reference CV for 10 replicates, the coefficient of variation (CV, %) of Ct value is not more than 10%.

Inter-batch difference

When the in-house precision reference is tested on three batches of kits under trial production upon repeated extraction and, the coefficient of variation (CV, %) of Ct value is not more than 10%.

Performance comparison

● Extraction efficiency comparsion

Efficiency comparsion of magnetic beads method and sample releaser

concentration
copies/mL

magnetic beads method

sample releaser

orfab

N

orfab

N

20000

28.01

28.76

28.6

29.15

2000

31.53

31.9

32.35

32.37

500

33.8

34

35.25

35.9

200

35.25

35.9

35.83

35.96

100

36.99

37.7

38.13

undet

The extraction efficiency of sample releaser was similar to that of magnetic beads method, and the concentration of pathogen could be 200Copies/mL.

● CV value comparison

Repeatability of sample releaser extraction

concentration:5000Copies/mL

ORF1ab

N

30.17

30.38

30.09

30.36

30.36

30.26

30.03

30.48

30.14

30.45

30.31

30.16

30.38

30.7

30.72

30.79

CV

0.73%

0.69%

When tested at 5,000 copies /mL, the CV of orFab and N was 0.73% and 0.69%, respectively.

Macro & Micro-Test Sample Release Reagent10


Product detail pictures:

High Quality for Isothermal Amplification - Macro & Micro-Test Sample Release Reagent – Macro & Micro-Test detail pictures

High Quality for Isothermal Amplification - Macro & Micro-Test Sample Release Reagent – Macro & Micro-Test detail pictures

High Quality for Isothermal Amplification - Macro & Micro-Test Sample Release Reagent – Macro & Micro-Test detail pictures

High Quality for Isothermal Amplification - Macro & Micro-Test Sample Release Reagent – Macro & Micro-Test detail pictures

High Quality for Isothermal Amplification - Macro & Micro-Test Sample Release Reagent – Macro & Micro-Test detail pictures


Related Product Guide:

We always follow the principle Quality Very first, Prestige Supreme. We have been fully committed to delivering our customers with competitively priced high-quality products and solutions, prompt delivery and experienced services for High Quality for Isothermal Amplification - Macro & Micro-Test Sample Release Reagent – Macro & Micro-Test , The product will supply to all over the world, such as: Maldives, Dubai, Boston, Why we can do these? Because: A, We are honest and reliable. Our items have high quality, attractive price, sufficient supply capacity and perfect service. B, Our geographical position has a big advantage . C, Various types: Welcome your inquiry, It might be highly appreciated.
  • The customer service staff is very patient and has a positive and progressive attitude to our interest, so that we can have a comprehensive understanding of the product and finally we reached an agreement, thanks!
    5 Stars By Fiona from Greece - 2017.05.21 12:31
    Problems can be quickly and effectively resolved, it is worth to be trust and working together.
    5 Stars By Delia from Afghanistan - 2018.06.19 10:42
    Write your message here and send it to us