Influenza A Virus Universal/H1/H3

Short Description:

This kit is used for qualitative detection of influenza A virus universal type, H1 type and H3 type nucleic acid in human nasopharyngeal swab samples.


Product Detail

Product Tags

Product name

HWTS-RT012 Influenza A Virus Universal/H1/H3 Nucleic Acid Multiplex Detection Kit(Fluorescence PCR)

Epidemiology

Influenza virus is a representative species of Orthomyxoviridae. It is a pathogen that seriously threatens human health. It can infect the host extensively. The seasonal epidemic affects about 600 million people worldwide and causes 250,000 ~500,000 deaths, of which influenza A virus is the main cause of infection and death. Influenza A virus is a single-stranded negative-stranded RNA. According to its surface hemagglutinin (HA) and neuraminidase (NA), HA can be divided into 16 subtypes, NA Divided into 9 subtypes. Among influenza A viruses, the subtypes of influenza viruses that can directly infect humans are: A H1N1, H3N2, H5N1, H7N1, H7N2, H7N3, H7N7, H7N9, H9N2 and H10N8. Among them, H1 and H3 subtypes are highly pathogenic, and are particularly worthy of attention.

Channel

FAM influenza A universal type virus nucleic acid
VIC/HEX influenza A H1 type virus nucleic acid
ROX influenza A H3 type virus nucleic acid
CY5 internal control

Technical Parameters

Storage

≤-18℃

Shelf-life 9 months
Specimen Type nasopharyngeal swab
Ct ≤38
CV ≤5.0%
LoD 500 Copies/μL
Specificity

No cross-reactivity with other respiratory samples such as Influenza A, Influenza B, Legionella pneumophila, Rickettsia Q fever, Chlamydia pneumoniae, Adenovirus, Respiratory Syncytial Virus, Parainfluenza 1, 2, 3 , Coxsackie virus, Echo virus, Metapneumovirus A1/A2/B1/B2, Respiratory syncytial virus A/B, Coronavirus 229E/NL63/HKU1/OC43, Rhinovirus A/B/C, Boca virus 1/2/3/4, Chlamydia trachomatis, adenovirus, etc. and human genomic DNA.

Applicable Instruments Applied Biosystems 7500 Real-Time PCR System

Applied Biosystems 7500 Fast Real-Time PCR Systems

QuantStudio®5 Real-Time PCR Systems

SLAN-96P Real-Time PCR Systems(Hongshi Medical Technology Co., Ltd.)

LightCycler®480 Real-Time PCR system

LineGene 9600 Plus Real-Time PCR Detection System (FQD-96A, Hangzhou Bioer technology)

MA-6000 Real-Time Quantitative Thermal Cycler (Suzhou Molarray Co., Ltd.)

BioRad CFX96 Real-Time PCR System 

BioRad CFX Opus 96 Real-Time PCR System

Work Flow

Nucleic Acid Extraction or Purification Reagent (YDP315-R) by Tiangen Biotech (Beijing) Co.,Ltd. The extraction should be carried out strictly according to the instructions for use. The extracted sample volume is 140μL, and the recommended elution volume is 60μL.

Option 2.

Macro & Micro-Test Viral DNA/RNA Kit (HWTS-3004-32, HWTS-3004-48, HWTS-3004-96) and Macro & Micro-Test Automatic Nucleic Acid Extractor (HWTS-3006C, HWTS-3006B). The extraction should be carried out strictly according to the instructions for use. The extracted sample volume is 200μL, and the recommended elution volume is 80μL.