Mycoplasma Pneumoniae (MP)
Product name
HWTS-RT024 Mycoplasma Pneumoniae(MP) Nucleic Acid Detection Kit(Fluorescence PCR)
Epidemiology
Mycoplasma pneumoniae (MP) is a kind of the smallest prokaryotic microorganism, which is between bacteria and virus, with cell structure but no cell wall. MP mainly causes human respiratory tract infection, especially in children and young people. It can cause human mycoplasma pneumonia, children’ s respiratory tract infection and atypical pneumonia. The clinical manifestations are various, most of which are severe cough, fever, chills, headache, sore throat. Upper respiratory tract infection and bronchial pneumonia are the most common. Some patients can develop from upper respiratory tract infection to severe pneumonia, severe respiratory distress and death may occur.
Channel
FAM | Mycoplasma pneumoniae |
VIC/HEX |
Internal Control |
Technical Parameters
Storage |
≤-18℃ |
Shelf-life | 12 months |
Specimen Type | Sputum、Oropharyngeal swab |
Ct | ≤38 |
CV | ≤5.0% |
LoD | 200 Copies/mL |
Specificity | a) Cross reactivity: there is no cross reactivity with Ureaplasma urealyticum, Mycoplasma genitalium, Mycoplasma hominis, Streptococcus pneumoniae, Chlamydia pneumoniae, Haemophilus influenzae, Klebsiella pneumoniae, Staphylococcus aureus, Mycobacterium tuberculosis, Legionella pneumophila, Pseudomonas aeruginosa, Acinetobacter baumannii, Influenza A virus, Influenza B virus, Parainfluenza virus type I/II/III/IV, Rhinovirus, Adenovirus, Human metapneumovirus, Respiratory syncytial virus and human genomic nucleic acid.
b)Anti-interference ability: there is no interference when the interfering substances were tested with the following concentrations: hemoglobin (50mg/L), bilirubin (20mg/dL), mucin (60mg/mL), 10% (v/v) human blood, levofloxacin (10μg/mL), moxifloxacin(0.1g/L), gemifloxacin (80μg/mL), azithromycin (1mg/mL), clarithromycin(125μg/mL), erythromycin(0.5g/L), doxycycline (50mg/L), minocycline (0.1g/L). |
Applicable Instruments | Applied Biosystems 7500 Real-Time PCR System
Applied Biosystems 7500 Fast Real-Time PCR Systems QuantStudio®5 Real-Time PCR Systems SLAN-96P Real-Time PCR Systems (Hongshi Medical Technology Co., Ltd.) LightCycler®480 Real-Time PCR system LineGene 9600 Plus Real-Time PCR Detection System (FQD-96A, Hangzhou Bioer technology) MA-6000 Real-Time Quantitative Thermal Cycler (Suzhou Molarray Co., Ltd.) BioRad CFX96 Real-Time PCR System BioRad CFX Opus 96 Real-Time PCR System |
Work Flow
(1) Sputum Sample
Recommended extraction reagent: Macro & Micro-Test Viral DNA/RNA Kit (HWTS-3017-50, HWTS-3017-32, HWTS-3017-48, HWTS-3017-96) (which can be used with Macro & Micro-Test Automatic Nucleic Acid Extractor (HWTS-3006C, HWTS-3006B)) by Jiangsu Macro & Micro-Test Med-Tech Co., Ltd. Add 200µL of normal saline to the processed precipitate. Subsequent extraction should be performed according to the instruction for use. The recommended elution volume is 80µL.Recommended extraction reagent: Nucleic Acid Extraction or Purification Reagent (YDP315-R). The extraction should be performed strictly according to the instruction for use. The recommended elution volume is 60µL.
(2) Oropharyngeal swab
Recommended extraction reagent: Macro & Micro-Test Viral DNA/RNA Kit (HWTS-3017-50, HWTS-3017-32, HWTS-3017-48, HWTS-3017-96) (which can be used with Macro & Micro-Test Automatic Nucleic Acid Extractor (HWTS-3006C, HWTS-3006B)) by Jiangsu Macro & Micro-Test Med-Tech Co., Ltd. The extraction should be performed according to the instruction for use. The recommended extraction volume of sample is 200µL, and the recommended elution volume is 80µL.Recommended extraction reagent: QIAamp Viral RNA Mini Kit (52904) or Nucleic Acid Extraction or Purification Reagent (YDP315-R). The extraction should be performed strictly according to the instruction for use. The recommended extraction volume of sample is 140µL, and the recommended elution volume is 60µL.