We're also concentrating on improving the things administration and QC program to ensure we could maintain terrific gain from the fiercely-competitive company for Malaria Pf, Malaria Pf, Hpv 16 Dna, Warmly welcome to cooperate and develop with us! we are going to continue to provide product or service with high quality and competitive rate.
OEM China Hpv Cervix - 28 Types of HPV Nucleic Acid Detection Kit (Fluorescence PCR ) – Macro & Micro-Test Detail:

Product name

28 Types of HPV Nucleic Acid Detection Kit (Fluorescence PCR )

Certificate

CE

Epidemiology

Cervical cancer is one of the most common malignant tumors in the female reproductive tract. The studies have shown that persistent infection and multiple infections of human papillomavirus is one of the important cause of cervical cancer. At present, there is still a lack of recognized effective treatment methods for HPV. Therefore, early detection and early prevention of cervical HPV is the key to blocking canceration. The establishment of a simple, specific and rapid pathogenic diagnostic method is of great significance in the clinical diagnosis of cervical cancer.

Features

● Multiplex PCR Amplification Technology.
● Internal control: Fully monitor the experimental process to ensure the quality of Experiments.
● High sensitivity: 25 Copies/reaction
● High specificity: No cross-reactivity with common respiratory pathogens for more accurate results.
● Convenient: One test for multiple results.

Channel

S/N Channel Type
PCR-Mix1 FAM 16, 18, 31, 56
VIC(HEX) Internal Control
CY5 45, 51, 52, 53
ROX 33, 35, 58, 66
PCR-Mix2 FAM 6, 11, 54, 83
VIC(HEX) 26, 44, 61, 81
CY5 40, 42, 43, 82
ROX 39, 59, 68, 73

PCR Amplification Conditions Setting

Step Cycles Temperature Time Collect Fluorescent Signals or Not
1 1 cycle 50℃ 2 mins No
2 1 cycle 95℃ 10 mins No
3 10 cycle 95℃ 15 s No
62℃ 20 s No
4 30 cycle 95℃ 15 s No
58℃ 30 s Yes

Technical Parameters

Storage ≤-18℃ in dark
Shelf-life 12 months
Specimen Type Cervical exfoliated cells
Ct ≤28
CV ≤5.0%
LoD 25 Copies/reaction
Specificity No cross-reactivity with common reproductive tract pathogens (such as ureaplasma urealyticum, genital tract chlamydia trachomatis, candida albicans, neisseria gonorrhoeae, trichomonas vaginalis, mold, gardnerella and other HPV types not covered in the kit, etc).
Applicable Instruments It can match the mainstream fluorescent PCR instruments on the market.
SLAN-96P Real-Time PCR Systems
ABI 7500 Real-Time PCR Systems
QuantStudio®5 Real-Time PCR Systems
LightCycler®480 Real-Time PCR Systems
LineGene 9600 Plus Real-Time PCR Detection Systems
MA-6000 Real-Time Quantitative Thermal Cycler

Main Components

Catalogue Number Component (50 tests/kit) Specification Quantity Component Description
HWTS-CC003A HPV WELL1 1.3mL/vial 1 vial Mixture of specific primers and probes of HPV16, 18, 31, 33, 35, 45, 51, 52, 53, 56, 58, 66
HPV WELL2 1.3mL/vial 1 vial Mixture of specific primers and probes of HPV6, 11, 26, 39, 40, 42, 43, 44, 54, 59, 61, 68, 73, 81, 82, 83
HPV Enzyme Mix 55uL/vial 1 vial Mixture of Taq DNA polymerase, Uracil-DNA Glycosylase and glycerin
HPV Positive Control WELL1 150μL/vial 1 vial Mixture of HPV16, 18, 31, 33, 35, 45, 51, 52, 53, 56, 58, 66 templates and Internal Control template
HPV Positive Control WELL2 150μL/vial 1 vial Mixture of 6, 11, 26, 39, 40, 42, 43, 44, 54, 59, 61, 68, 73, 81, 82, 83 templates
HPV Blank Control 300μL/vial 1 vial RNase/DNase free H2O

Total PCR Solution

Option 1.

Fluorescence PCR3

Option 2.

Fluorescence PCR4


Product detail pictures:

OEM China Hpv Cervix - 28 Types of HPV Nucleic Acid Detection Kit (Fluorescence PCR ) – Macro & Micro-Test detail pictures

OEM China Hpv Cervix - 28 Types of HPV Nucleic Acid Detection Kit (Fluorescence PCR ) – Macro & Micro-Test detail pictures

OEM China Hpv Cervix - 28 Types of HPV Nucleic Acid Detection Kit (Fluorescence PCR ) – Macro & Micro-Test detail pictures

OEM China Hpv Cervix - 28 Types of HPV Nucleic Acid Detection Kit (Fluorescence PCR ) – Macro & Micro-Test detail pictures


Related Product Guide:

Persisting in High quality, Prompt Delivery, Aggressive Price, now we have established long-term cooperation with consumers from equally overseas and domestically and get new and old clients' large comments for OEM China Hpv Cervix - 28 Types of HPV Nucleic Acid Detection Kit (Fluorescence PCR ) – Macro & Micro-Test , The product will supply to all over the world, such as: Costa rica, Buenos Aires, Nepal, Our products have been obtained more and more recognition from foreign clients, and established long term and cooperative relationship with them. We`ll provide the best service for every customer and sincerely welcome friends to work with us and establish the mutual benefit together.
  • This company has the idea of better quality, lower processing costs, prices are more reasonable, so they have competitive product quality and price, that's the main reason we chose to cooperate.
    5 Stars By Ingrid from Czech - 2018.09.29 13:24
    The manufacturer gave us a big discount under the premise of ensuring the quality of products, thank you very much, we will select this company again.
    5 Stars By Anastasia from Indonesia - 2017.09.28 18:29
    Write your message here and send it to us