Product name
18 Types of High-risk Human Papilloma Virus Nucleic Acid Detection Kit (Fluorescence PCR)
Certificate
CE
Epidemiology
Cervical cancer is one of the most common malignant tumors in the female reproductive tract. Studies have shown that persistent infection and multiple infections of human papillomavirus are one of the important causes of cervical cancer.
Reproductive tract HPV infection is common among women with sexual life. According to statistics, 70% to 80% of women may have HPV infection for once at least in their lifetime, but most infections are self-limiting, and more than 90% of infected women will develop an effective immune response that could clear the infection between 6 and 24 months without any long-term health intervention. Persistent high-risk HPV infection is the main cause of cervical intraepithelial neoplasia and cervical cancer.
The worldwide study results showed that the presences of high-risk HPV DNA were detected in 99.7% of cervical cancer patients. Therefore, the early detection and prevention of cervical HPV are the key to blocking canceration. The establishment of a simple, specific and rapid pathogenic diagnostic method is of great significance in the clinical diagnosis of cervical cancer.
Features
● Multiplex PCR Amplification Technology.
● Internal control: Fully monitor the experimental process to ensure the quality of Experiments.
● High specificity: No cross-reactivity with common respiratory pathogens for more accurate results.
● High sensitivity: 25 copies/reaction.
● Convenient: One test for multiple results.
Channel
FAM | HPV 18 |
VIC (HEX) | HPV 16 |
ROX | HPV 26, 31, 33, 35, 39, 45, 51, 52, 53, 56, 58, 59, 66, 68, 73, 82 |
CY5 | Internal control |
PCR Amplification Conditions Setting
Step | Cycles | Temperature | Time | Collect Fluorescent Signals or Not |
1 | 1 cycle | 50℃ | 2 mins | No |
2 | 1 cycle | 95℃ | 10 mins | No |
3 | 10 cycle | 95℃ | 15 s | No |
62℃ | 20 s | No | ||
4 | 30 cycle | 95℃ | 15 s | No |
58℃ | 30 s | Yes |
Technical Parameters
Storage | ≤-18℃ in dark |
Shelf-life | 24 months |
Specimen Type | Cervical exfoliated cells |
Ct | ≤28 |
CV | ≤5.0% |
LoD | 25 Copies/reaction |
Specificity | No cross-reactivity with common reproductive tract pathogens (such as ureaplasma urealyticum, genital tract chlamydia trachomatis, candida albicans, neisseria gonorrhoeae, trichomonas vaginalis, mold, gardnerella and other HPV types not covered in the kit, etc). |
Applicable Instruments | It can match the mainstream fluorescent PCR instruments on the market. |
SLAN-96P Real-Time PCR Systems | |
ABI 7500 Real-Time PCR Systems | |
QuantStudio®5 Real-Time PCR Systems | |
LightCycler®480 Real-Time PCR Systems | |
LineGene 9600 Plus Real-Time PCR Detection Systems | |
MA-6000 Real-Time Quantitative Thermal Cycler |
Main Components
Catalogue Number | Component (50 tests/kit) | Specification | Quantity | Component Description |
HWTS-CC011A | 18 HPV Reaction Buffer | 1.25mL/vial | 1 vial | Amplification reaction reagents and kinds of primers, probes |
18 HPV Positive Control | 600μL/vial | 1 vial | Mixture of HPV 16, 18, 33 and their internal control plasmids | |
18 HPV Blank Control | 600μL/vial | 1 vial | DNase/RNase free H2O |
Total PCR Solution
Option 1.
1. Sampling
2. Nucleic acid extraction
3. Add samples to the machine
Option 2.
1. Sampling
2. Extraction-free
3. Add samples to the machine
Product detail pictures:
Related Product Guide:
The corporate keeps towards the operation concept scientific administration, superior quality and performance primacy, client supreme for OEM/ODM Manufacturer Hpv 16 18 - 18 Types of High-risk Human Papilloma Virus Nucleic Acid Detection Kit – Macro & Micro-Test , The product will supply to all over the world, such as: Southampton, Switzerland, Guinea, Customer's satisfaction is always our quest, creating value for customers is always our duty, a long term mutual-beneficial business relationship is what we are doing for. We are an absolutely reliable partner for yourself in China. Of course, other services, like consulting, can be offered too.
By Martina from Mexico - 2017.10.13 10:47
Hope that the company could stick to the enterprise spirit of Quality, Efficiency, Innovation and Integrity, it will be better and better in the future.
By Jodie from Brasilia - 2018.11.28 16:25