Quality Inspection for Mycobacterium Tuberculosis Test - Mycobacterium Tuberculosis DNA Detection Kit (Isothermal Amplification) – Macro & Micro-Test

Short Description:


Product Detail

Product Tags

Related Video

Feedback (2)

go on to boost, to be certain item quality in line with market and buyer standard demands. Our firm has a excellent assurance procedure happen to be established for Flu A & Flu B Combo Kit, Ebv Pcr Test, Ffn Test, Our service concept is honesty, aggressive, realistic and innovation. With your support, we will grow much better.
Quality Inspection for Mycobacterium Tuberculosis Test - Mycobacterium Tuberculosis DNA Detection Kit (Isothermal Amplification) – Macro & Micro-Test Detail:

Product name

Adenovirus Type 41 Nucleic Acid Detection Kit(Fluorescence PCR)

Certificate

CE

Packaging Size

1. Liquid product: 50 tests/kit

2. Freeze-dried product (penicillin vial): 20 tests/kit, 50 tests/kit

3. Freeze-dried product (8-tube strips): 48 tests/kit

Intended Use

This kit is used for the qualitative detection of adenovirus nucleic acid in stool samples in vitro.

Epidemiology

Adenovirus (Adv) belongs to the Adenovirus family. Adv can proliferate and cause disease in cells of the respiratory tract, gastrointestinal tract, urethra, and conjunctiva. It is mainly infected through the gastrointestinal tract, respiratory tract or close contact, especially in swimming pools with insufficient disinfection, which can increase the chance of transmission and cause outbreaks[1-2].

Adv mainly infects children. The gastrointestinal tract infections in children are mainly type 40 and 41 in group F. Most of them have no clinical symptoms, and some cause diarrhea in children. Its mechanism of action is to invade the small intestinal mucosa of children, making the intestinal mucosal epithelial cells smaller and shorter, and the cells degenerate and dissolve, resulting in intestinal absorption dysfunction and diarrhea. Abdominal pain and bloating may also occur, and in severe cases, the respiratory system, central nervous system, and extraintestinal organs such as liver, kidney, and pancreas may be involved and the disease may be aggravated[3-5].

Features

Multiplex PCR Amplification Technology

Internal control: Fully monitor the experimental process to ensure the quality of Experiments.

High sensitivity: 300Copies/mL

High specificity: No cross-reactivity with common respiratory pathogens or bacteria for more accurate results.

Rapid: Rapid PCR amplification, test results can be obtained in 40 minutes.

Channel

FAM: Adenovirus type 41 nucleic acid

VIC (HEX): Internal control

Amplification Conditions Setting

Step Cycles Temperature Time Collect Fluorescent Signals or Not
1 1 cycle 50℃ 2mins No
2 1 cycle 95℃ 1min No
3 40 cycles 95℃ 5s No
55℃ 15s Yes

Technical Parameters

Storage:

Liquid: ≤-18℃ In dark

Lyophilization: ≤30℃

Shelf-life: 12 months

Specimen Type: Stool samples

Ct: ≤38

CV: ≤5.0%

LoD: 300Copies/mL

Specificity: Use the kits to detect other respiratory pathogens (such as influenza A virus, influenza B virus, respiratory syncytial virus, parainfluenza virus, rhinovirus, human metapneumovirus, etc.) or bacteria (streptococcus pneumoniae, klebsiella pneumoniae, pseudomonas aeruginosa, acinetobacter baumannii, staphylococcus aureus, etc.) and common gastrointestinal pathogens group A rotavirus, escherichia coli, etc. There is no cross-reactivity with all the pathogens or bacteria mentioned above.

Applicable Instruments: It can match the mainstream fluorescent PCR instruments on the market.

ABI 7500 Real-Time PCR Systems

ABI 7500 Fast Real-Time PCR Systems

SLAN-96P Real-Time PCR Systems

QuantStudio®5 Real-Time PCR Systems

LightCycler®480 Real-Time PCR Systems

LineGene 9600 Plus Real-Time PCR Detection Systems

MA-6000 Real-Time Quantitative Thermal Cycler

Main Components

Liquid product

Catalogue Number

Component (50 tests/kit)

Specification

Quantity

Component Description

HWTS-RT113B

ADV 41 Reaction Buffer

1.25mL /vial

1 vial

Amplification reaction reagents, adenovirus type 41 primer probes, internal control primer probes, etc.

ADV 41 Positive Control

250μL/vial

1 vial

Adenovirus and internal control plasmids mixture.

ADV 41 Blank Control

250μL/vial

1 vial

DNase/RNase free H2O

Lyophilized product

Component Character Catalogue Number Component Description
HWTS-RT113A HWTS-RT113C HWTS-RT113Z
Specification/Quantity(20 tests/kit) Specification/Quantity(50 tests/kit) Specification/Quantity(48 tests/kit)
ADV 41 Reaction Buffer lyophilized 1 bottle 1 bottle 8-tube strips, 6 strips Amplification reaction reagents, adenovirus type 41 primer probes, internal control primer probes, etc.
ADV 41 Positive Control lyophilized 1 vial 1 vial 1 vial Adenovirus and internal control plasmids mixture.
ADV 41 Blank Control Liquid 1 vial, 250μL/vial 1 vial, 250μL/vial 1 vial, 250μL/vial DNase/RNase free H2O
ADV 41 Reconstituted Solution Liquid 1 vial, 650μL/vial 1 vial, 1.25mL/vial 1 vial, 1.21mL/vial DNase/RNase free H2O, etc.

Total PCR Solution

Option 1.

Option1Option 2.

Option2

[References]

[1] Use of quantitative molecular diagnostic methods to identify causes of diarrhoea in children: a reanalysis of the GEMS case-control study[J]. Lancet, 2016, 388(10051):1291-1301.

[2] Burden and aetiology of diarrhoeal disease in infants and young children in developing countries (the Global Enteric Multicenter Study, GEMS): a prospective, case-control study.[J]. Lancet, 2013, 382(9888):209-222.

[3] Liu M, Worley S, Arrigain S, et al. Respiratory viral infections within one year after pediatric lung transplant[J]. Transplant Infectious Disease, 2010, 11(4):304-312.

[4] Dey R S, Ghosh S, Chawla-Sarkar M, et al. Circulation of a Novel Pattern of Infections by Enteric Adenovirus Serotype 41 among Children below 5 Years of Age in Kolkata, India[J]. Journal of Clinical Microbiology, 2011, 49(2):500-505.

[5] Lekana-Douki S E, Kombila-Koumavor C, Nkoghe D, et al. Molecular epidemiology of enteric viruses and genotyping of rotavirus A, adenovirus and astrovirus among children under 5 years old in Gabon[J]. International journal of infectious diseases: IJID: official publication of the International Society for Infectious Diseases, 2015, 34(C):90-95.

Adenovirus Type (1)
Adenovirus Type (2)
Adenovirus Type (3)
Adenovirus Type (4)


Product detail pictures:

Quality Inspection for Mycobacterium Tuberculosis Test - Mycobacterium Tuberculosis DNA Detection Kit (Isothermal Amplification) – Macro & Micro-Test detail pictures

Quality Inspection for Mycobacterium Tuberculosis Test - Mycobacterium Tuberculosis DNA Detection Kit (Isothermal Amplification) – Macro & Micro-Test detail pictures

Quality Inspection for Mycobacterium Tuberculosis Test - Mycobacterium Tuberculosis DNA Detection Kit (Isothermal Amplification) – Macro & Micro-Test detail pictures

Quality Inspection for Mycobacterium Tuberculosis Test - Mycobacterium Tuberculosis DNA Detection Kit (Isothermal Amplification) – Macro & Micro-Test detail pictures

Quality Inspection for Mycobacterium Tuberculosis Test - Mycobacterium Tuberculosis DNA Detection Kit (Isothermal Amplification) – Macro & Micro-Test detail pictures


Related Product Guide:

Our primary intention should be to offer our clientele a serious and responsible enterprise relationship, delivering personalized attention to all of them for Quality Inspection for Mycobacterium Tuberculosis Test - Mycobacterium Tuberculosis DNA Detection Kit (Isothermal Amplification) – Macro & Micro-Test , The product will supply to all over the world, such as: Swiss, Chicago, Montreal, The development of our company not only needs the guarantee of quality, reasonable price and perfect service, but also relies on our customer's trust and support! In the future, we will continue with the most professional and high quality service to provide the most competitive price, Together with our customers and achieve win-win! Welcome to inquiry and consult!
  • The factory workers have a good team spirit, so we received high quality products fast, in addition, the price is also appropriate, this is a very good and reliable Chinese manufacturers.
    5 Stars By olivier musset from Moscow - 2018.06.03 10:17
    We are a small company that has just started, but we get the company leader's attention and gave us a lot of help. Hope we can make progress together!
    5 Stars By Diego from Romania - 2017.09.28 18:29
    Write your message here and send it to us