Six Respiratory Pathogens

Short Description:

This kit is used for the qualitative detection of respiratory syncytial virus (RSV), adenovirus (Adv), human metapneumovirus (hMPV), rhinovirus (Rhv), parainfluenza virus type I/II/III (PIVI/II/III), and Mycoplasma pneumoniae (MP) nucleic acids in human oropharyngeal swab samples.


Product Detail

Product Tags

Product name

HWTS-RT175-Six Respiratory Pathogens Nucleic Acid Detection Kit (Fluorescence PCR )

Epidemiology

Respiratory infections are the most common group of human diseases that can occur in any gender, age and geographic area and are one of the most significant causes of morbidity and mortality in populations worldwide. The common clinical respiratory pathogens include respiratory syncytial virus, adenovirus, human metapneumovirus, rhinovirus, parainfluenza virus (I/II/III) and Mycoplasma pneumoniae. Clinical signs and symptoms caused by respiratory tract infections are relatively similar, but the treatment, efficacy, and duration of the disease vary among infections caused by different pathogens. Currently, the main methods for laboratory detection of the above respiratory pathogens include: virus isolation, antigen detection and nucleic acid detection. This kit assists in the diagnosis of respiratory viral infections by detecting and identifying specific viral nucleic acids in individuals with signs and symptoms of respiratory infections, in combination with other clinical and laboratory findings.

Technical Parameters

Storage

≤-18℃

Shelf-life 12 months
Specimen Type Oropharyngeal swab sample
Ct Adv, PIV, MP, RhV, hMPV, RSV Ct≤38
CV <5.0%
LoD LoD of Adv, MP, RSV, hMPV, RhV and PIV are all 200Copies/mL
Specificity The results of the cross-reactivity test showed that there is no cross-reactivity between the kit and novel coronavirus, influenza A virus, influenza B virus, human bocavirus, cytomegalovirus, herpes simplex virus type 1, varicella zoster virus, EBV, pertussis bacillus, Chlamydophila pneumoniae, Corynebacterium spp, Escherichia coli, Haemophilus influenzae, Lactobacillus spp, Legionella pneumophila, C. catarrhalis, and attenuated strains of Mycobacterium tuberculosis, Neisseria meningitidis, Neisseria spp, Pseudomonas aeruginosa, Staphylococcus aureus, Staphylococcus epidermidis, Streptococcus pneumoniae, Streptococcus pyogenes, Streptococcus salivarius, Actinobacillus baumannii, Narrow-feeding maltophilic monococci, Burkholderia maltophilia, Streptococcus striatus, Nocardia sp., Sarcophaga viscosa, Citrobacter citriodora, Cryptococcus spp, Aspergillus fumigatus, Aspergillus flavus, Pneumatobacteria spp, Candida albicans, Rohypnogonia viscera, oral streptococci, Klebsiella pneumoniae, Chlamydia psittaci, Rickettsia q fever and human genomic nucleic acids.

Anti-interfering ability: mucin (60 mg/mL), human blood, benfotiamine (2 mg/mL), oxymetazoline (2 mg/mL), sodium chloride (20 mg/mL), beclomethasone (20 mg/mL), dexamethasone (20 mg/mL), flunitrazolone (20 μg/mL), triamcinolone acetonide (2 mg/mL), budesonide (1 mg/ mL), mometasone (2 mg/mL), fluticasone (2 mg/mL), histamine hydrochloride (5 mg/mL), intranasal live influenza virus vaccine, benzocaine (10%), menthol (10%), zanamivir (20 mg/mL), ribavirin (10 mg/L), paramivir (1 mg/mL), oseltamivir (0.15 mg/mL), mupirocin (20 mg/mL), tobramycin (0.6 mg/mL), UTM, saline, guanidine hydrochloride (5 M/L), Tris (2 M/L), ENTA-2Na (0.6 M/L), trilostane (15%), isopropyl alcohol (20%), and potassium chloride (1 M/L) were subjected to an interference test, the results showed that there was no interference reaction to the detection results of the pathogen at the above concentrations of interfering substances.

Applicable Instruments SLAN-96P Real-Time PCR Systems

Applied Biosystems 7500 Real-Time PCR System

QuantStudio®5 Real-Time PCR Systems

LineGene 9600 Plus Real-Time PCR Detection System

MA-6000 Real-Time Quantitative Thermal Cycler

BioRad CFX96 Real-Time PCR System

BioRad CFX Opus 96 Real-Time PCR System

Work Flow

Macro & Micro-Test General DNA/RNA Kit (HWTS-3019) (which can be used with Macro & Micro-Test Automatic Nucleic Acid Extractor (HWTS-3006C, (HWTS-3006B) by Jiangsu Macro & Micro-Test Med-Tech Co., Ltd. are recommended for the sample extraction and the subsequent steps should be conducted in strict accordance with the IFU of the Kit. 


  • Previous:
  • Next:

  • Write your message here and send it to us