Top Suppliers Ebv Pcr Test - EB Virus Nucleic Acid Detection Kit(Fluorescence PCR) – Macro & Micro-Test

Short Description:


Product Detail

Product Tags

Related Video

Feedback (2)

We've got a highly efficient group to deal with inquiries from shoppers. Our purpose is 100% client fulfillment by our product high-quality, price tag & our staff service and enjoy a superb reputation amongst clientele. With quite a few factories, we will provide a wide variety of Malaria Ag Pf Detecation Kit, Gbs Test, Hepatitis B Test Kit, We sincerely welcome friends to negotiate business and start cooperation with us. We hope to join hands with friends in different industries to create a brilliant future.
Top Suppliers Ebv Pcr Test - EB Virus Nucleic Acid Detection Kit(Fluorescence PCR) – Macro & Micro-Test Detail:

Product name

EB Virus Nucleic Acid Detection Kit(Fluorescence PCR)

Certificate

CE

Epidemiology

EBV (Epstein-barr virus), or human herpesvirus type 4, is a common human herpesvirus[1]. In recent years, a large number of studies have proved that EBV is associated with occurrence and development of nasopharyngeal cancer, Hodgkin’s disease, T/Natural killer celllymphoma, Burkitt’s lymphoma, breast cancer, gastric cancer and other malignant tumors. And it is also closely associated with post-transplantlymphoproliferative disorders, post-transplant smooth muscle tumor and acquired immunedeficiency syndrome(AIDS) related lymphoma, multiple sclerosis, primary central nervous system lymphoma or leiomyosarcoma[2-4].

Features

● Multiplex PCR Amplification Technology.
● Internal control: Fully monitor the experimental process to ensure the quality of Experiments.
● High sensitivity: 500Copies/mL.
● Convenient: One test for multiple results.

Channel

FAM: EBV
VIC (HEX): Internal control

PCR Amplification Conditions Setting

Step Cycles Temperature Time Collect Fluorescent Signals or Not
1 1 cycle 50℃ 2mins No
2 1 cycle 95℃ 5mins No
3 40 cycles 95℃ 15s No
58℃ 30s Yes

Technical Parameters

Storage ≤-18℃ In dark
Shelf-life 12 months
Specimen Type Whole blood, Plasma, Serum
Ct ≤38
CV ≤5.0%
LoD 500Copies/mL

Specificity: It has no cross-reactivity with other pathogens (such as human herpesvirus 1, 2, 3, 6, 7, 8, hepatitis B virus, cytomegalovirus, influenza A, etc.) or bacteria (Staphylococcus aureus, Candida albicans, etc.)

Applicable Instruments: It can match the mainstream fluorescent PCR instruments on the market.
SLAN-96P Real-Time PCR Systems.
ABI 7500 Real-Time PCR Systems.
QuantStudio®5 Real-Time PCR Systems.
LightCycler®480 Real-Time PCR Systems.
LineGene 9600 Plus Real-Time PCR Detection Systems.
MA-6000 Real-Time Quantitative Thermal Cycler.

Main Components

Catalogue Number Component (50 tests/kit) Specification Quantity Component Description
HWTS-OT061A EB Reaction Buffer 1.175mL/vial 1 vial Amplification reaction reagents, EB virus primer probes, internal reference primer probes, etc.
EB Enzyme Mix 75μL/vial 1 vial Taq enzyme, UDG enzyme, etc.
EB Positive Control 600μL/vial 1 vial Mixed solution of viral target gene and internal reference
EB Blank Control 600μL/vial 1 vial DNase/RNase free H2O

Total PCR Solution

EB Virus Nucleic Acid Detection Kit(Fluorescence PCR)6

Reference

[1] ohen JI, Jaffe ES, Dale JK, et al. Characterization and treatment of chronic active Epstein-Barr virus disease: a 28-year experience in the United States[J]. Blood, 2011, 117(22): 5835-5849.
[2] Jahangiryan A, Kheirandish M, Samiee S, et al. Determination of Epstein-Barr virus (EBV) incidence in umbilical cord blood (UCB) and assessment of virus DNA via Real-time PCR[J]. Annals of Cancer Research and Therapy, 2021, 29(1):114-120.
[3] Petersson F. Nasopharyngeal carcinoma:a review[J].Semin Diagn Pathol, 2015, 32(1):54-73. [4]Chen J N, He D, Tang F, et al. Epstein-Barr virus-associated gastric carcinoma:a newly defined entity[J]. J Clin Gastroenterol, 2012, 46(4):262-271.


Product detail pictures:

Top Suppliers Ebv Pcr Test - EB Virus Nucleic Acid Detection Kit(Fluorescence PCR) – Macro & Micro-Test detail pictures

Top Suppliers Ebv Pcr Test - EB Virus Nucleic Acid Detection Kit(Fluorescence PCR) – Macro & Micro-Test detail pictures

Top Suppliers Ebv Pcr Test - EB Virus Nucleic Acid Detection Kit(Fluorescence PCR) – Macro & Micro-Test detail pictures

Top Suppliers Ebv Pcr Test - EB Virus Nucleic Acid Detection Kit(Fluorescence PCR) – Macro & Micro-Test detail pictures

Top Suppliers Ebv Pcr Test - EB Virus Nucleic Acid Detection Kit(Fluorescence PCR) – Macro & Micro-Test detail pictures


Related Product Guide:

Bear Customer initially, High-quality first in mind, we work closely with our prospects and supply them with efficient and specialist companies for Top Suppliers Ebv Pcr Test - EB Virus Nucleic Acid Detection Kit(Fluorescence PCR) – Macro & Micro-Test , The product will supply to all over the world, such as: UK, Iceland, Swedish, Excellent quality comes from our adherence to every detail, and customer satisfaction comes from our sincere dedication. Relying on advanced technology and industry reputation of good cooperation, we try our best to provide more quality products and services to our customers, and all of us are willing to strengthen exchanges with domestic and foreign customers and sincere cooperation, to build a better future.
  • Sales manager is very enthusiastic and professional, gave us a great concessions and product quality is very good,thank you very much!
    5 Stars By Pamela from California - 2018.11.04 10:32
    After the signing of the contract, we received satisfactory goods in a short term, this is a commendable manufacturer.
    5 Stars By Fanny from Oman - 2017.01.28 19:59
    Write your message here and send it to us