Trichomonas Vaginalis Nucleic Acid

Short Description:

This kit is used for the qualitative detection of Trichomonas vaginalis nucleic acid in human urogenital tract secretion samples.


Product Detail

Product Tags

Product name

HWTS-UR011A-Trichomonas Vaginalis Nucleic Acid Detection Kit (Isothermal Amplification)

Epidemiology

Trichomonas vaginalis (TV) is a flagellate parasitic in the human vagina and urinary tract, which mainly causes trichomonas vaginitis and urethritis, and is a sexually transmitted infectious disease. Trichomonas vaginalis has strong adaptability to the external environment, and the crowd is generally susceptible. There are about 180 million infected people worldwide, and the infection rate is highest among women aged 20 to 40. Trichomonas vaginalis infection can increase the susceptibility to human immunodeficiency virus (HIV), human papillomavirus (HPV), etc. Existing statistical surveys show that Trichomonas vaginalis infection is closely related to adverse pregnancy, cervicitis, infertility, etc., and is related to the occurrence and prognosis of reproductive tract malignant tumors such as cervical cancer, prostate cancer, etc. Accurate diagnosis of Trichomonas vaginalis infection is an important link in the prevention and treatment of the disease, and it is of great significance to prevent the spread of the disease.

Channel

FAM TV nucleic acid
ROX

Internal Control

Technical Parameters

Storage

Liquid: ≤-18℃

Shelf-life 9 months
Specimen Type urethral secretions, vaginal secretions
Tt <30
CV ≤10.0%
LoD 3 Copies/µL
Specificity

No cross-reactivity with other urogenital tract samples, such as Candida albicans, Chlamydia trachomatis, Ureaplasma urealyticum, Neisseria gonorrhoeae, Group B streptococcus, Mycoplasma hominis, Mycoplasma genitalium, Herpes simplex virus, Human papillomavirus, Escherichia coli, Gardnerella vaginalis, staphylococcus aureus and Human Genomic DNA, etc.

Applicable Instruments

Easy Amp Real-time Fluorescence Isothermal Detection System (HWTS 1600)

Applied Biosystems 7500 Real-Time PCR System

Applied Biosystems 7500 Fast Real-Time PCR Systems

QuantStudio®5 Real-Time PCR Systems

SLAN-96P Real-Time PCR Systems

LightCycler®480 Real-Time PCR system

LineGene 9600 Plus Real-Time PCR Detection System

MA-6000 Real-Time Quantitative Thermal Cycler

BioRad CFX96 Real-Time PCR System

BioRad CFX Opus 96 Real-Time PCR System

Work Flow

Option 1.

Recommended extraction reagent: Macro & Micro-Test Sample Release Reagent (HWTS-3005-8) produced by Jiangsu Macro & Micro-Test Med-Tech Co., Ltd.

Option 2.

Recommended extraction reagent: Macro & Micro-Test Viral DNA/RNA Kit (HWTS-3001, HWTS-3004-32, HWTS-3004-48, HWTS-3004-96) and Macro & Micro-Test Automatic Nucleic Acid Extractor (HWTS-3006) produced by Jiangsu Macro & Micro-Test Med-Tech Co., Ltd. 


  • Previous:
  • Next:

  • Write your message here and send it to us