Xinjiang Hemorrhagic Fever Virus
Product name
HWTS-FE007B/C Xinjiang Hemorrhagic Fever Virus Nucleic Acid Detection Kit (Fluorescence PCR)
Epidemiology
Xinjiang hemorrhagic fever virus was first isolated from the blood of patients with hemorrhagic fever in the Tarim Basin, Xinjiang, China and the hard ticks captured locally, and got its name. Clinical manifestations include fever, headache, bleeding, hypotensive shock, etc. The basic pathological changes of this disease are systemic capillary dilatation, congestion, increased permeability and fragility, resulting in varying degrees of congestion and hemorrhage in the skin and mucous membranes as well as tissues of various organs throughout the body, with degeneration and necrosis of solid organs such as liver, adrenal gland, pituitary gland, etc., and jelly-like edema in the retroperitoneum.
Channel
FAM | Xinjiang Hemorrhagic Fever Virus |
ROX |
Internal Control |
Technical Parameters
Storage |
≤-18℃ |
Shelf-life | 9 months |
Specimen Type | fresh serum |
Tt | ≤38 |
CV | <5.0% |
LoD | 1000Copies/mL |
Specificity |
No cross-reactivity with other respiratory samples such as Influenza A, Influenza B, Legionella pneumophila, Rickettsia Q fever, Chlamydia pneumoniae, Adenovirus, Respiratory Syncytial Virus, Parainfluenza 1, 2, 3 , Coxsackie virus, Echo virus, Metapneumovirus A1/A2/B1/B2, Respiratory syncytial virus A/B, Coronavirus 229E/NL63/HKU1/OC43, Rhinovirus A/B/C, Boca virus 1/2/3/4, Chlamydia trachomatis, adenovirus, etc. and human genomic DNA. |
Applicable Instruments | Applied Biosystems 7500 Real-Time PCR Systems,
Applied Biosystems 7500 Fast Real-Time PCR Systems QuantStudio®5 Real-Time PCR Systems SLAN-96P Real-Time PCR Systems LightCycler®480 Real-Time PCR system LineGene 9600 Plus Real-Time PCR Detection Systems MA-6000 Real-Time Quantitative Thermal Cycler BioRad CFX96 Real-Time PCR System BioRad CFX Opus 96 Real-Time PCR System |
Work Flow
Recommended extraction reagent: Macro & Micro-Test Viral DNA/RNA Kit (HWTS-3017) (which can be used with Macro & Micro-Test Automatic Nucleic Acid Extractor (HWTS-EQ011)) by Jiangsu Macro & Micro-Test Med-Tech Co., Ltd. The extraction should be conducted according to the instruction for use of this extraction reagent. The extracted sample volume is 200µL, and the recommended elution volume is 80µL.
Recommended extraction reagent: QIAamp Viral RNA Mini Kit (52904) by QIAGEN and Nucleic Acid Extraction or Purification Reagent (YDP315-R). The extraction should be conducted in strict accordance with instructions for use. The extracted sample volume is 140µL, and the recommended elution volume is 60µL.